Anti-Magnetic Small Current Transformer

Features

  • Work properly under 300mT magnetic field
  • Phase shift error < 5′, DC tolerance < 3%
  • High accuracy with turns ratio 1:2500
  • Maximum primary current as high as 80A
  • Plastic case with removable busbar, easy to install

Applications

  • Anti-tamper energy meters
  • Single/three phase electricity meters
  • Electrical measuring instruments

Specifications

Part NumberDI80-25A
Description Anti-Magnetic Small Current Transformer
Structure Of Winding Toroidal
Phase Single
Input / Output 10(80)A/4mA
Max. Current 80 A
Turns Ratio 1:2500
Phase Shift Error5′ (20% Rated Current)
Burden (Rb) 20 Ω
Accuracy Class 0.1 Class
DC Resistance (25°C)125 Ω ± 10%
DC Immunity Test<3%
Anti-magnetic Performanceupto 300mT
Core Inside Nanocrystalline & Fe-based Amorphous
Encapsulation Plastic Case & Epoxy Resin Filled
Busbar Type Removable
Mounting Method Through-holes For Mounting
Application Meters, Instruments
Accept Customized Yes

Dimensions

Dimensions of Anti-Magnetic Small Current Transformer
Dimensions of Anti-Magnetic Small Current Transformer
Anti-Magnetic Small Current Transformer
Tagged on: