Three Phase Latching Relay
Three Phase Latching Relay

Three Phase Magnetic Latching Relay

Features

  • Size: 110×68×30mm
  • Max current 100/150A
  • Single/double coil 6~48VDC
  • 6-M6 screw for mounting

Specifications

Contact Specification

Basic ModelXY-306 (XY-33A/B)
DescriptionThree Phase Latching Relay
Dimensions (mm)110×68×30
Contact Form3A/3B
Contact MaterialAgSnO2 (Silver Alloy)
Max Switching Power25000 VA, 37500 VA
Max Switching Current (Anti-load)60A, 80A, 100A, 120A
Max Switching Voltage250VAC

Coil Resistance (20°C)

Rated Coil Voltage6VDC9VDC12VDC24VDC48VDC
Single Coil Rated Current (±10%mA)833556417208104
Double Coil Rated Current (±10%mA)16661111833416208
Single Coil (±10%Ω)7.216.228.8115.2460.8
Double Coil (±10%Ω)3.6+3.68.1+8.114.4+14.457.6+57.6230.4+230.4

Coil Specification (20°C)

Pick-up Voltage≤80% Rated Coil Voltage
Drop-out Voltage≤80% Rated Coil Voltage
Max. Applicable Voltage≤120% Rated Coil Voltage
Pick-up Time(At Rated Voltage)≤30ms
Drop-out Time(At Rated Voltage)≤30ms
Bounce Time≤100ms
Power Consumption5 W(Sigle Coil); 10 W(Double Coil)

Characteristics

Ambient Temp.-40~+55 °C
Anti-vibration10~55Hz, 0.5mm (Double Amplitude)
Anti-shock98m/s2, 11ms
Relative Humidity45%~85%
Contact Resistance≤2.0mΩ
Insulation Resistance≥1000MΩ (500VDC)

Dielectric Strength

Between Contacts1000 VAC 50/60Hz (1 Minute)
Between Contact & Coil4000 VAC 50/60Hz (1 Minute)
Between Contacts & Contact4500 VAC 50/60Hz (1 Minute)

Service Life

Electrical Life≥1×104 OPS
Mechaniacal Life≥1×105 OPS

External Diagram

XY-306, Three Phase Latching Relay

Wiring Diagram

3-Phase Magnetic Latching Relay
XY-306, Three Phase Latching Relay

Related Products

Three Phase Magnetic Latching Relay
Tagged on: